🢒 Air Conditioning (A/C) Refrigerant Low Temperature Sensor Replacement
Tools Required
J 39400-A
Halogen Leak Detector
Removal Procedure
Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
Disconnect the electrical connector from the A/C low temperature sensor.
Unscrew the A/C low temperature sensor from the refrigerant line.
Installation Procedure
Install the A/C low temperature sensor to the refrigerant line.
Connect the electrical connector to the A/C low temperature sensor.
Recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
Leak test the fittings of the repaired or reinstalled component using
J 39400-A
.