Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics Connector End View Reference: Lighting Systems Connector End Views | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 |
Does the I/P compartment lamp remain illuminated? | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
3 | Disconnect the I/P compartment lamp switch. Does the I/P compartment lamp remain illuminated? | Go to Step 5 | Go to Step 4 |
4 | Inspect for poor connections at the harness connector of the I/P compartment lamp switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
5 | Repair a short to ground in the glove box lamp control circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 7 | -- |
6 | Replace the I/P compartment lamp switch. Did you complete the replacement? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |