The memory seat system consists of the following components:
• | Memory Seat Module (MSM) |
• | Seat Front Vertical Motor |
• | Seat Rear Vertical Motor |
• | Lumbar Horizontal Motor |
• | Seat Horizontal Position Sensor |
• | Seat Front Vertical Position Sensor |
• | Seat Rear Vertical Position Sensor |
• | Seat Recline Position Sensor |
• | Headrest Position Sensor |
• | Lumbar Horizontal Positional Sensor |
• | Lumbar Vertical Position Sensor |
• | Driver Door Switch Assembly (DDSA) |
• | PWR Seat Circuit Breaker 30 A |
Personalization Option
The memory seat module (MSM) cannot perform memory recall functions
unless the Personalization Option is activated. The personalization option
is located in the dash integration module (DIM). The DIM reports the personalization
option setting to the MSM, as well as other receiving modules, via a class 2
message each time the ignition switch is cycled to the ON position. The MSM
will then store the personalization option setting and examine it before making
a memory seat adjustment. The personalization option setting stored within
the MSM will not change until the personalization option setting in the DIM
is changed and the ignition switch is cycled to the ON position.
Seat Adjuster Switch
Battery positive is supplied at all times to the seat adjuster switch
from the MEM T&T Fuse located in the rear fuse block. When the power seat
switches are pressed they send a 12 V signal to the MSM. The MSM commands
the selected seat motor to move in response to the switch inputs.
MSM Power and Grounds
Battery positive voltage is supplied at all times to the MSM from the
PWR SEAT Circuit Breaker located in the rear fuse block. This voltage is used
to power up MSM and also to apply power to the seat motors when commanded.
Battery positive is also supplied to the MSM from the MEM T&T Fuse located
in the rear fuse block. The MSM monitors this voltage to determine the state
of power at seat adjuster switch. If voltage is not detected from this circuit,
the MSM will cancel or disable all memory recall functions. The MSM is grounded
through the module ground circuit and G 201.
Seat Motors
The MSM controls the movement for each of the seat directional
motors and the 2 lumbar motors. Refer to
Lumbar Support Description and Operation
. All of the motors operate
independently of each other. Each motor contains a electronic circuit breaker
(PTC), which will reset only after voltage has been removed from the motor.
There are 4 motors that move the position of the seat. These
are the seat horizontal motor, front vertical motor, rear vertical motor and
the recline motor. The horizontal motor moves the entire seat forward and
rearward. Both vertical motors can run simultaneously when the seat switch
is operated in order to move the entire seat up and down. Or they can be selected
independently to vertically tilt the front or rear of the seat up and down.
The recline motor moves the angle of the seat back forward or rearward.
All seat motors are reversible. For example, when a seat switch is pressed
to move the entire seat forward, battery positive voltage is applied through
the power seat horizontal forward switch signal circuit to the MSM. In response
to this signal, the MSM applies battery positive voltage through the driver
seat horizontal motor forward control circuit and ground through the driver
seat horizontal motor rearward control circuit to the motor. The motor runs
in order to drive the entire seat forward. Moving the entire seat rearward
works similarly to moving the entire seat forward, except that battery positive
voltage and ground are applied on the opposite circuits causing the motor
to run in the opposite direction. All of the seat motors are powered this
way.
The MSM provides each seat motor with a soft stop that will actually
stop the motor just before the physical end-of-travel. This decreases the
stress on each motor. If a motor reaches the end-of-travel due a soft stop
and the seat switch is released and then activated again, the seat will move
a short distance farther to the physical travel limit.
Position Sensors
The seat position sensors are potentiometers which are either attached
directly to the motor's transmission cable or are an internal part of the
motor. The MSM supplies a 5 volt reference voltage via the 5 volt
reference circuit and ground via the sensor low reference circuit to the respective
seat position sensors. When the motor or cable rotates, the resistance of
the potentiometer varies changing the feedback voltage of the position sensor
signal circuit. The voltage varies from 0.25 volts to 4.75 volts.
The MSM monitors this voltage signal to determine the position of the seat.
When a memory set command is received, the MSM records the seat position by
storing the feedback voltage from each position sensor. When a memory recall
command is received, the MSM moves the motors until the position sensor feedback
voltages equals the feedback voltages stored in memory. For the easy exit
function, only seat position sensor feedback voltages are recorded and only
the seat motors are controlled. The lumbar support is not involved in the
easy exit function.
Memory Functions
The driver's door switch assembly (DDSA) receives the signals from the
memory function switch. The DDSA then sends a message via the simple bus interface
to the driver door module (DDM) indicating that a memory function signal
has been received. The DDM then sends a message to the memory seat module
(MSM) via class 2 serial data line. The current seat position may be
recorded for 2 different drivers. To record a position, adjust the
drivers seat (including the lumbar adjustments) and both outside mirrors to
a comfortable position, then press the memory set button. Within 5 seconds,
press button 1 (for driver 1). A second mirror and seating
position may be programmed by repeating the above steps and pressing button 2
(for driver 2). When the MSM receives a memory set message, the MSM
records the feedback voltages from the position sensors for the appropriate
driver. Two personalized exit positions can be set by first recalling driver
position 1 or 2, positioning the steering wheel and seat (except the
lumbar and headrest) in the desired exit positions and then pressing the MEMORY
SET button, and within 5 seconds, pressing the EXIT button. When the
MSM receives a set easy exit message, the MSM records the feedback voltages
from the three seat position sensors and the recline position sensor for the
appropriate driver.
When the 1 or 2 button is pressed, a single chime is sounded
through the radio in order to acknowledge the signal and the MSM receives
the memory recall message. The MSM then applies battery positive voltage to
the motors until the position sensor feedback voltages equal the feedback
voltages stored in memory for the appropriate driver. When the EXIT button
is pressed, a single chime is sounded in order to acknowledge the signal and
the MSM receives the easy exit message. The MSM then applies battery positive
voltage to the seat motors until the position sensor feedback voltages equal
the feedback voltages stored in memory for the appropriate driver.
Memory recall will not work if the shift lever is out of NEUTRAL (N)
or PARK (P).
Recall Personalization
When a keyless entry transmitter is used in order to unlock the vehicle's
doors, the remote keyless entry (RKE) module communicates the unlock command
and which driver performed the command to the MSM via a class 2 message. There
are 2 personalized recall options when the MSM receives an unlock message:
• | Recall immediately upon receipt of the RKE message |
• | Do not recall upon receipt of an RKE message. Memory recall functions
are only performed with the memory buttons |
Memory Inhibit/Enable
The memory seat module (MSM) receives the ignition switch signal and
the gear selector position via class 2 messages. When the ignition
switch is in the OFF position, memory record, memory recall, personalization
recall, and exit recall functions are all allowed. When the ignition switch
is in the ON position and the gear selector is in the PARK position, only
the recall personalization function is deactivated and all other memory functions
are allowed. When the ignition switch is in the ON position and the gear selector
is out of the PARK position, only memory record is allowed, all other memory
seat functions are not allowed.