Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Ambient air temperature display is inaccurate. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 | Inspect the ambient air temperature sensor for obstructions or improper mounting. Did you find and correct the condition? | Go to Step 6 | Go to Step 3 |
3 | Inspect for poor connections at the harness connector of the ambient air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 6 | Go to Step 4 |
4 | Test the ambient air temperature sensor resistance. Refer to Sensor Resistance Table . Does the resistance measure near the Sensor Resistance Table value? | System OK | Go to Step 5 |
5 | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Sensor Replacement . Did you complete the repair? | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |