Secondary Air Injection Shut-Off Valve Outlet Pipe/Hose Replacement - Bank 2 for Cadillac Seville - RHD 2001
Removal Procedure
- Remove the bank 2 AIR shut-off valve. Refer to
Secondary Air Injection Shutoff Valve Replacement - Bank 2
.
- Move the upper radiator hose to gain access to the two nuts securing
the outlet pipe to the exhaust manifold.
- Remove the two nuts and the bank 2 AIR outlet pipe.
Installation Procedure
- Install the bank 2 AIR outlet pipe and new gasket to the
exhaust manifold.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the two nuts securing the bank 2
AIR outlet pipe to the exhaust manifold.
Tighten
Tighten the two nuts to 9 N·m (80 lb in).
- Install the bank 2 AIR shut-off valve. Refer to
Secondary Air Injection Shutoff Valve Replacement - Bank 2
.