The numbers below refer to the step numbers on the diagnostic table.
This step tests for a blower motor that does not operate regardless of the desired blower motor speed.
This step tests for a blower motor that operates, yet does not accurately respond to the desired blower motor speed.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the auxiliary air distribution outlets. | |||
1 | Did you perform the Diagnostic System Check? | Go to Step 2 | |
2 |
Is the blower motor OFF? | Go to Step 3 | |
Does the blower motor operate at all? | Go to Step 4 | ||
Does the auxiliary blower motor operate in each speed position? | Go to Step 5 | ||
5 | Place the auxiliary mode switch in each position. Is the air flow sufficient from the correct outlets in each mode? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 6 |
6 | Test the ignition 3 voltage circuit of the auxiliary mode actuator and the auxiliary HVAC control assembly for an open, short to ground or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 7 |
7 | Test the ground circuit of the auxiliary mode actuator and the auxiliary HVAC control assembly for an open, short to voltage or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 8 |
8 |
Does the voltage change for each position selected? | Go to Step 10 | Go to Step 9 |
9 | Test the auxiliary mode control circuit for an open, short to ground or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 12 |
10 |
Did you find and correct the condition? | Go to Step 15 | Go to Step 11 |
11 | Inspect for poor connections at the harness connector of the auxiliary mode actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 13 |
12 | Inspect for poor connections at the harness connector of the auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 14 |
13 | Replace the auxiliary mode actuator. Refer to Auxiliary Mode Valve Actuator Replacement . Did you complete the replacement? | Go to Step 15 | -- |
14 | Replace the auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Module Replacement . Did you complete the replacement? | Go to Step 15 | -- |
15 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |