Removal Procedure
- Disassemble the A/C refrigerant components. Refer to the appropriate repair
procedure.
- Remove the O-ring seal from the A/C refrigerant component.
- Inspect the O-ring seal for signs of damage.
- Inspect the A/C refrigerant components for damage or burrs. Repair or
replace as necessary.
- Discard the O-ring seal.
Installation Procedure
- Inspect the new O-ring seal for any sign or cracks, cuts, or damage. Replace
if necessary.
- Using a lint-free clean, dry cloth, carefully clean the sealing surfaces
of the A/C refrigerant components.
Important: DO NOT allow any of the mineral base 525 viscosity refrigerant oil on
the new O-ring seal to enter the refrigerant system.
- Lightly coat the new O-ring seal and thread fitting with mineral base 525 viscosity
refrigerant oil.
Important: DO NOT reuse O-ring seals.
- Carefully slide the new O-ring seal onto the A/C refrigerant component.
- The O-ring seal must be fully seated.
- Assemble the A/C components.
Refer to the appropriate repair procedure.