GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Remove the RH insulator panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side in Instrument Panel, Gages and Console.
  2. Caution: Unplug the blower motor before removal. Blower motor case contact with any ground may start the fan and cause personal injury.

    Important: Blower speed is controlled by an internal pulse width module that is internal to the blower motor assembly and is not serviced separately.

  3. Disconnect the blower motor electrical connector.

  4. Object Number: 907907  Size: SH
  5. Remove the blower motor retaining screws.
  6. Remove the blower motor from the HVAC module.

Installation Procedure


    Object Number: 907907  Size: SH
  1. Install the blower motor to the HVAC module.
  2. Notice: Refer to Fastener Notice in the Preface section.

  3. Install the blower motor retaining screws.
  4. Tighten
    Tighten the screws to 1.6 N·m (14 lb in).

  5. Connect the blower motor electrical connector.
  6. Install the RH insulator panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side in Instrument Panel, Gages and Console.