Tools Required
J39765-A Fuel Sender Lock Ring Tool
Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection .
- Remove the right fuel tank. Refer to
Fuel Tank Replacement - Right Side .
- Place the fuel tank on a suitable work surface.
- Disconnect the evaporative emissions (EVAP) purge line (4) from the fuel tank module.
- Disconnect the fuel tank module harness connector (5).
- Disconnect the fuel tank pressure (FTP) sensor harness connector (1).
- If replacing the fuel tank module, remove the FTP sensor (2). Refer to
Fuel Tank Pressure Sensor Replacement .
Important: The fuel tank module is spring loaded and will spring upward when the locking ring is removed.
- Using the
J39765-A (1), remove the fuel tank module locking ring (2), by rotating the
J39765-A in a counterclockwise direction.
- Carefully remove the fuel tank module (2) from the fuel tank half way with the jet lines connected. Ensure not to damage the fuel level float arm.
- Disconnect the internal fuel line quick-connect fittings from the fuel tank module ports, noting the location of the lines for installation.
- Remove the fuel tank module from the fuel tank using care not to damage the fuel level float arm.
- Remove the fuel tank module O-ring (3) from the fuel tank opening.
Installation Procedure
- Install a NEW fuel tank module O-ring (3) to the fuel tank opening.
Important: Pull on each internal fuel line to ensure that the quick-connect fittings are secure.
- Pull the internal fuel lines up through the fuel tank module opening and connect the internal fuel line quick-connect fittings to the fuel tank module ports in the location noted during disassembly.
- Install the fuel tank module lock ring (1) into position on the fuel tank module.
- Install the fuel tank module into the fuel tank, using care not to damage the fuel level sensor arm.
- Compress and align the fuel tank module.
- Using the
J39765-A (1), fully lock the fuel tank module lock ring (2) in place, by rotating the
J39765-A in a clockwise direction.
- Using a digital multi-meter, verify the full and empty readings resistance reading of the fuel tank module. Turn the fuel tank upside down to achieve the full tank reading.
Resistance
- Install the FTP sensor (2), if previously removed. Refer to
Fuel Tank Pressure Sensor Replacement .
- Connect the FTP sensor harness connector (1).
- Connect the fuel tank module harness connector (5).
- Connect the EVAP purge line (4) to the fuel tank module.
- Install the right fuel tank. Refer to
Fuel Tank Replacement - Right Side .
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection .
- Perform the following procedure in order to test for leaks:
14.1. | Turn ON the ignition switch, for 2 seconds. |
14.2. | Turn OFF the ignition, for 10 seconds. |
14.3. | Turn ON the ignition. |
14.4. | Inspect for fuel leaks. |
Specification
• | Fuel pump on: 400 kPa (58 psi) |
• | Fuel pump off: 359 kPa (52 psi) |
- Program the transmitters. Refer to