GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    •  Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    •  Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Exhaust Valve Solenoid Supply Voltage

P166A

1

P166A

--

Ground

1

1

1

--

1. Exhaust Vibration/Noise - Exhaust Flow Control System Malfunction

Circuit/System Description

Exhaust tail pipe flow valve control module receives throttle position sensor and RPM information via serial data from powertrain control module (PCM). The exhaust tail pipe flow valve control module uses this information to determine if to command exhaust tail pipe flow control valve solenoid ON or OFF. When commanded OFF the exhaust tail pipe flow control valve solenoid allows vacuum to flow to close exhaust valve.

Reference Information

Schematic Reference

Exhaust System Schematics

Connector End View Reference

Exhaust System Connector End Views

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Scan Tool Data List for exhaust tail pipe flow valve control module

Circuit/System Testing

  1. Ignition OFF, disconnect the exhaust tail pipe flow control valve solenoid connector.
  2. Ignition ON, use scan tool to command exhaust flow control relay ON, measure for 10 volts or above between the exhaust tail pipe flow control valve solenoid supply voltage circuit and ground.
  3. If under 10 volts, test for open/high resistance in exhaust tail pipe flow control valve solenoid supply voltage circuit. If circuit test normal replace the exhaust tail pipe flow valve control module.
  4. Connect a test lamp between the exhaust tail pipe flow control valve solenoid supply voltage circuit and ground circuit. Verify that the test lamp illuminates.
  5. If the test lamp does not illuminate, test the ground circuit for open or high resistance.
  6. If all circuits test normal replace the exhaust tail pipe flow control valve solenoid.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Exhaust Tail Pipe Flow Control Valve Solenoid Replacement
    •  Control Module References for exhaust tail pipe flow valve control module replacement, setup, and programming