Table 1: | Roof |
Table 2: | HVAC |
Table 3: | Driver Door Module (DDM) |
Table 4: | Passenger Door Module (PDM) |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Ignition ACCY or RUN, Vehicle in PARK, Valet Switch Inactive/OFF, Folding Top Closed and Cargo Cover installed | |||
Battery Voltage Signal | Outputs | Volts | Varies |
Deck Lid Ajar Status | History Roof | Known / Unknown | Known |
Deck Lid Ajar Status | History Trunk | Known / Unknown | Known |
Deck Lid Ajar Status | Inputs | Deck Closed / Deck Ajar | Deck Closed |
Deck Lid Closed Switch | Inputs | Active / Inactive | Inactive |
Deck Lid Extended | Inputs | Active / Inactive | Inactive |
Deck Lid Latch Status | History Roof | Cleared / Not Cleared | Cleared |
Deck Lid Latch Status | History Trunk | Clear / Not Clear | Clear |
Deck Lid Latch Switch | Inputs | Deck Closed / Deck Open | Deck Closed |
Driver Window Operation | History Roof | Enabled / Disabled | Enabled |
Driver Window Position Status | History Roof | Ok / Out of Limit | Ok |
Folding Top Calibrated | History Roof | Yes / No | Yes |
Folding Top Close Reference Position | Inputs | Counts | Varies |
Folding Top Open Reference Position | Inputs | Counts | Varies |
Folding Top Position Sensor | Inputs | Counts | Varies |
Folding Top Status | Inputs | Extended / Mid / Retracted / Invalid | Extended |
Front Tonneau Position Sensor | Inputs | Counts | Varies |
Front Tonneau Status | Inputs | Invalid / Tonneau Open / Mid / Tonneau Closed | Tonneau Closed |
Front Tonneau Close Reference Position | Inputs | Counts | Varies |
Front Tonneau Open Reference Position | Inputs | Counts | Varies |
Header Latch Limit Switches | Inputs | Latched / Mid / Unlatched / Invalid | Latched |
Limit Switch Supply Voltage | History Roof | Present / Not Present | Present |
Limit Switch Supply Voltage | History Trunk | Present / Not Present | Present |
Luggage Barrier In Place | History Roof | Yes/No | Yes |
Luggage Barrier Limit Switch | Inputs | Open / Closed | Closed |
Motor Feedback | Outputs | Amps | 0.00 amps |
Motor Feedback Current | History Roof | OK / High | OK |
Motor Feedback Current | History Trunk | OK / High | OK |
Motor X Direction Command | Outputs | On/Off | Off |
Motor Y Direction Command | Outputs | On/Off | Off |
Passenger Window Operation | History Roof | Enabled / Disabled | Enabled |
Passenger Window Position Status | History Roof | Ok / Out of Limit | Ok |
Position Sensor Status | History Trunk | Ok / Error | Ok |
Position Sensors Status | History Roof | Ok / Error | Ok |
Power Mode Active | History Roof | Yes / No | Yes |
Pump Motor Temp. Sensor | Outputs | Fahrenheit / Celsius | Varies |
Pump Over Temperature Sensor | History Roof | Overtemp / Normal | Normal |
Pump Over Temperature Sensor | History Trunk | Over Temp / Normal | Normal |
Rear Tonneau Close Reference Position | Inputs | Counts | Varies |
Rear Tonneau Open Reference Position | Inputs | Counts | Varies |
Rear Tonneau Position Sensor | Inputs | Counts | Varies |
Rear Tonneau Status | Inputs | Invalid / Tonneau Open / Mid / Tonneau Closed | Tonneau Closed |
System Timer | History Roof | OK / Expired | OK |
System Timer | History Trunk | OK / Expired | OK |
System Voltage | History Roof | OK / Low | OK |
System Voltage | History Trunk | Ok / Low | Ok |
Too Cold For Top Operation | History Roof | Yes / No | No |
Top Closed Limit Switch | Inputs | Active / Inactive | Active |
Top Control | History Roof | Inhibited/Enabled | Enabled |
Top Control Switch | Inputs | Idle / Top Closed / Top Open / Invalid | Idle |
Top Position Error | History Trunk | Yes / No | No |
Trunk Control | History Trunk | Inhibited / Enabled | Enabled |
Valet Status | History Roof | Active / Inactive | Inactive |
Valet Switch Status | History Trunk | Active / Inactive | Inactive |
Valve 1 Command | Outputs | On/Off | Varies |
Valve 2 Command | Outputs | On/Off | Varies |
Valve 3 Command | Outputs | On/Off | Varies |
Valve 4 Command | Outputs | On/Off | Varies |
Valve 5 Command | Outputs | On/Off | Varies |
Vehicle in PARK | History Roof | Yes / No | Yes |
Vehicle in PARK | History Trunk | Yes / No | Yes |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Ignition ACCY, Vehicle in PARK, Valet Switch Inactive/OFF, Folding Top Closed | |||
Valet Switch | Data | Active/Inactive | Inactive |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Ignition ACCY, Vehicle in PARK, Valet Switch Inactive/OFF, Folding Top Closed | |||
Battery Voltage Signal | Data | Volts | Varies |
Window Normalization | Data | Yes / No | Yes |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Ignition ACCY, Vehicle in PARK, Valet Switch Inactive/OFF, Folding Top Closed | |||
Battery Voltage Signal | Data | Volts | Varies |
Window Normalization | Data | Yes / No | Yes |