The potentiometer service kit contains one potentiometer (2) and 3 electrical connector retainer clips (1). Find and install the retainer clip that matches the clip on the potentiometer that you are replacing.
Position the potentiometer (1) to the link (3). Align the D-shaped rotor into the D-shaped hole (4) in the link.
Rotate the potentiometer until the screw holes (2) are aligned.
Apply LOCTITE™ Blue, GM P/N 12345382 (Canadian P/N 10953489) or equivalent to the bolts.