GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Reverse Lamp Relay B+

1

1

--

--

Backup Lamp Relay Control

1

1

1

--

Backup Lamp Control

1

1

1

--

Backup Lamp - Left Ground

--

1

1

--

Backup Lamp - Right Ground

--

1

1

--

1. Backup Lamps Malfunction

Circuit/System Description

The underhood fuse block supplies battery voltage through the STOP/B/U/ LPS fuse to the coil and switch terminals of the REVERSE LAMP Relay located in the body control module (BCM). When the transmission is placed in the REVERSE position, the transmission control module (TCM) sends a serial data message to the BCM. The message indicates that the gear selector is in the REVERSE position. The BCM grounds the back up lamp relay control circuit of the reverse lamp relay. This energizes the reverse lamp relay, closing the switch side contacts and provides battery voltage to the REVERSE LAMPS fuse through to the backup lamps. The backup lamps are permanently grounded at G301. With both power and ground the backup lamps illuminate. Once the driver moves the gear selector out of the REVERSE position, a message is sent by the TCM via serial data requesting the BCM to remove ground from the back up lamp relay control circuit. This opens the REVERSE LAMP Relay switch contacts turning OFF the backup lamps.

Reference Information

Schematic Reference

Exterior Lights Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Exterior Lighting Systems Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

  1. Ignition OFF, disconnect the reverse lamp relay.
  2. Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal R8 and ground.
  3. If the test lamp illuminates, test the control circuit for a short to voltage.
  4. Verify that a test lamp illuminates between the B+ circuit terminal S8 and ground.
  5. If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse 5 is open, test the control circuit terminal R8 for a short to ground. If the circuit tests normal, test or replace the reverse lamp relay.
  6. Verify that a test lamp illuminates between the B+ circuit terminal S9 and ground.
  7. If the test lamp does not illuminate, test the B+ circuit for an open/high resistance.
  8. Disconnect the harness connector at the inoperative backup lamp.
  9. Ignition OFF, exterior lamps OFF, test for less than 5 ohms between the ground circuit terminal G and ground.
  10. If greater than the specified range, test the ground circuit for an open/high resistance.
  11. Connect the harness connector at the inoperative backup lamp.
  12. Connect a 10A fused jumper wire between the B+ circuit terminal S9 and the control circuit terminal R8. Verify the backup lamps are activated.
  13. If the backup lamps do not activate, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the inoperative backup lamp.
  14. Connect a test lamp between the B+ circuit terminal S8 and the control circuit terminal R9.
  15. Command the BackupLamps ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
  16. If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM.
    If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.
  17. If all circuits test normal, test or replace the reverse lamp relay.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Relay Replacement
    •  Backup Lamp Replacement
    •  Control Module References for BCM replacement, setup, and programming