• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Reverse Lamp Relay B+ | 1 | 1 | -- | -- |
Backup Lamp Relay Control | 1 | 1 | 1 | -- |
Backup Lamp Control | 1 | 1 | 1 | -- |
Backup Lamp - Left Ground | -- | 1 | 1 | -- |
Backup Lamp - Right Ground | -- | 1 | 1 | -- |
1. Backup Lamps Malfunction |
The underhood fuse block supplies battery voltage through the STOP/B/U/ LPS fuse to the coil and switch terminals of the REVERSE LAMP Relay located in the body control module (BCM). When the transmission is placed in the REVERSE position, the transmission control module (TCM) sends a serial data message to the BCM. The message indicates that the gear selector is in the REVERSE position. The BCM grounds the back up lamp relay control circuit of the reverse lamp relay. This energizes the reverse lamp relay, closing the switch side contacts and provides battery voltage to the REVERSE LAMPS fuse through to the backup lamps. The backup lamps are permanently grounded at G301. With both power and ground the backup lamps illuminate. Once the driver moves the gear selector out of the REVERSE position, a message is sent by the TCM via serial data requesting the BCM to remove ground from the back up lamp relay control circuit. This opens the REVERSE LAMP Relay switch contacts turning OFF the backup lamps.
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse 5 is open, test the control circuit terminal R8 for a short to ground. If the circuit tests normal, test or replace the reverse lamp relay. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for an open/high resistance. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the backup lamps do not activate, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the inoperative backup lamp. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |