Tools Required
J 39400-A
Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Remove the battery. Refer to
Battery Replacement
.
- Remove the intake manifold. Refer to
Intake Manifold Replacement
.
- Disconnect the front evaporator inlet line from the body retaining clip (1).
- Disconnect the refrigerant pressure sensor electrical connector (2).
- Disconnect and remove the A/C tube connectors from the evaporator rear line assembly. Refer to
Air Conditioning Line/Tube Connector Removal/Replacement
.
Important: Immediately cap or tape the open A/C components immediately in order to prevent contamination.
- Disconnect the front evaporator inlet line from the evaporator rear line assembly.
- Remove and discard O-rings.
- Cap or tape the front evaporator inlet line.
- Disconnect the A/C compressor line from the evaporator rear line assembly.
- Remove and discard the O-rings.
- Cap or tape the front evaporator line and A/C compressor line.
- Remove the heater pipe bracket retaining nut (1) from the cowl stud.
- Remove the TXV block fitting nut (2).
- Disconnect the evaporator rear line assembly from the TXV (3).
- Disconnect the evaporator rear line assembly from the retainer bracket.
- Remove the rear evaporator line assembly from the vehicle.
- Remove and discard the seal washers.
- Cap or tape the TXV (3).
Installation Procedure
Important: If replacing the evaporator rear line assembly, add the specified amount of PAG oil directly to the evaporator rear line assembly. Refer to
Refrigerant System Capacities
.
- Remove the cap or tape from the TXV (3).
- Install new seal washers to the evaporator rear line assembly . Refer to
Sealing Washer Replacement
.
- Install the evaporator rear line assembly to the vehicle.
- Connect the evaporator rear line assembly to the retainer bracket.
- Connect the evaporator rear line assembly to the TXV (3).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the TXV block fitting nut (2).
Tighten
Tighten the nut to 20 N·m (15 lb ft).
- Install the heater pipe bracket retaining nut (1) to the cowl stud.
Tighten
Tighten the nut to 10 N·m (7 lb ft).
- Remove cap or tape from the front evaporator line and A/C compressor line.
- Install new O-rings to the rear evaporator line assembly. Refer to
O-Ring Replacement
.
- Connect the A/C compressor line to the evaporator rear line assembly.
- Connect the front evaporator line to the evaporator rear line assembly.
- Connect the A/C tube connectors onto the evaporator rear line assembly. Refer to
Air Conditioning Line/Tube Connector Removal/Replacement
.
- Connect the refrigerant pressure sensor electrical connector (2).
- Connect the front evaporator inlet line to the body retaining clip (1).
- Install the intake manifold. Refer to
Intake Manifold Replacement
.
- Install the battery. Refer to
Battery Replacement
.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using
J 39400-A
.