GM Service Manual Online
For 1990-2009 cars only

Removal Procedure


    Object Number: 1239401  Size: SH
  1. Remove the engine sight shield. Refer to Intake Manifold Sight Shield Replacement.
  2. Remove the water pump and generator drive belt tensioner. Refer to Water Pump and Generator Belt Replacement.
  3. Disconnect the actuator solenoid electrical connector.
  4. Remove the left exhaust camshaft position (CMP) actuator solenoid bolts.
  5. Remove the left exhaust CMP actuator solenoid.

Installation Procedure

Caution: DO NOT remove the camshaft position actuator magnet unless it needs to be replaced. The camshaft position actuator magnet is precisely aligned to the camshaft position actuator oil control valve on the end of the camshaft during engine assembly. If the camshaft position actuator magnet is removed and/or needs to be replaced, it will be necessary to realign the camshaft position actuator magnet to the camshaft position actuator oil control valve after the camshaft position actuator housing is installed to the cylinder head. Failure to realign the camshaft position actuator magnet to the camshaft position actuator oil control valve can lead to poor engine performance and engine component damage.

To allow for CMP actuator solenoid to CMP actuator oil control valve alignment, DO NOT install the NEW CMP actuator solenoid alignment plugs at this time.

Camshaft Position Actuator Solenoid Alignment Procedure


    Object Number: 1239401  Size: SH
  1. Make an alignment pin from drill rod 15/64 inch diameter and at least 50 mm (1.97 in) long.
  2. If necessary remove the black alignment plug on the actuator and verify that the alignment pin will pass through the CMP actuator solenoid alignment hole.
  3. Verify that the alignment pin will fit into the alignment hole in the CMP actuator oil control valve.
  4. Apply a 2 mm (0.079 in) bead of RTV GM P/N 12378521 (Canadian P/N 88901148) around the flange of the CMP actuator solenoid.
  5. Install the CMP actuator solenoid over the oil control valve.
  6. Install the alignment pin through the solenoid alignment hole and into the oil control valve alignment hole.
  7. Caution: Refer to Fastener Caution in the Preface section.

  8. With the alignment pin in place, install the CMP actuator solenoid bolts and tighten to 8 N·m (71 lb in).
  9. Remove the alignment pin.
  10. Install a NEW CMP actuator solenoid plug.
  11. Connect the electrical connector to the actuator solenoid.
  12. Install the water pump and generator drive belt tensioner. Refer to Water Pump and Generator Belt Replacement.
  13. Install the engine sight shield. Refer to Intake Manifold Sight Shield Replacement.