Removal Procedure
- Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement.
- Loosen the air cleaner resonator duct clamp (1).
- Remove the air cleaner resonator duct.
- Remove the mass air flow (MAF/intake air temperature (IAT) sensor bolts (2).
- Remove the MAF/IAT sensor (3) and seal.
Installation Procedure
- Install the NEW MAF/IAT sensor (3) and seal.
Caution: Refer to Fastener Caution in the Preface section.
- Install the MAF/IAT sensor bolts (2) and tighten to
4 N·m (35 lb in).
- Install the air cleaner resonator duct.
- Tighten the air cleaner resonator duct clamp (1).
- Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement.