• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
5-Volt Reference | P0532 | P0532 | P0533 | -- |
Signal | P0532 | P0532 | P0533 | -- |
Low Reference | -- | P0533 | -- | -- |
The engine control module (ECM) monitors the high side refrigerant pressure through the A/C refrigerant pressure sensor. The ECM supplies a 5-volt reference and a low reference to the sensor. Changes in the A/C refrigerant pressure causing the A/C refrigerant pressure sensor signal to the ECM to vary. When the pressure is high, the signal voltage is high. When the pressure is low, the signal voltage is low. When pressure is high, the ECM commands the cooling fans ON. When pressure is too high or too low, the ECM will not allow the A/C compressor clutch to engage.
• | The engine is running. |
• | Any of the conditions for setting the DTC are met for 15 seconds |
The ECM detects that the A/C pressure is less than 1 psi.
The ECM detects that the A/C pressure is more than 428 psi.
• | The malfunction indicator lamp (MIL) will not illuminate. |
• | The ECM stores the DTC in the Failure Records. |
• | The A/C compressor clutch is disabled. |
• | The DTC will become history if the ECM no longer detects a failure. |
• | The history DTC will clear after 40 consecutive ignition cycles have occurred without a malfunction. |
Automatic HVAC Description and Operation
Control Module References for scan tool information
Ignition ON, with the engine OFF. Observe the scan tool A/C High Side Pressure Sensor parameter. The reading should be between 0-428 psi and change with A/C pressure.
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit terminal for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |