GM Service Manual Online
For 1990-2009 cars only

Object Number: 1566332  Size: LF

Callout

Component Name

1

NEW Fluid Pump Seal

2

Torque Converter (with Fluid Pump) Housing Assembly

Caution: Ensure the turbine shaft (O-ring) seal is not installed prior to installing the torque converter housing assembly. The seal may become cut or damaged during installation of the torque converter housing assembly.

3

Bolt M10 x 50 (Qty: 9)

Caution: Refer to Fastener Caution in the Preface section.

Procedure

Tighten in the sequence shown.

Tighten
72 N·m (53 lb ft)

4

NEW Turbine Shaft (O-Ring) Seal