Removal Procedure
- Remove the RH insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side.
Warning: Unplug the blower motor before removal. Blower motor case contact with any ground may start the fan and cause personal injury.
Note: Blower speed is controlled by an internal pulse width module that is internal to the blower motor assembly and is not serviced separately.
- Disconnect the blower motor electrical connector.
- Remove the blower motor retaining screws.
- Remove the blower motor from the HVAC module.
Installation Procedure
- Install the blower motor to the HVAC module.
Caution: Refer to Fastener Caution in the Preface section.
- Install the blower motor retaining screws and tighten to
1.6 N·m (14 lb in).
- Connect the blower motor electrical connector.
- Install the RH insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side.