Noise from a generator may be due to electrical or mechanical noise. Electrical noise (magnetic whine) usually varies with the ampere load placed on the generator and is a normal operating characteristic of all generators. When diagnosing a noisy generator, it is important to remember that loose or misaligned components around the generator may transmit the noise into the passenger compartment and that replacing the generator may not solve the problem.
Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
DEFINITION: Noise from the generator may be due to electrical or mechanical noise. Electrical noise (magnetic whine) usually varies with the ampere load placed on the generator and is a normal operating characteristic of all generators. When diagnosing a noisy generator, it is important to remember that loose or misaligned components around the generator may transmit the noise into the passenger compartment and that replacing the generator may not solve the problem. | ||||||||
1 | Test the generator for proper operation using the J 41450-B CS Generator Tester. Refer to Generator Not Operating Properly . Is the generator operating properly? | -- | ||||||
2 |
Has the noise stopped? | -- | ||||||
3 |
Does the generator shaft spin smoothly and without any roughness or grinding noise? | -- | ||||||
4 | Inspect the generator for a loose pulley and/or pulley nut. Is the generator pulley or pulley nut loose? | -- | ||||||
5 |
Is the pulley or the shaft damaged? | -- | ||||||
6 |
Has the noise decreased or stopped? | 100 N·m (74 lb ft) | System OK | |||||
7 |
Has the noise decreased or stopped? | -- | System OK | |||||
8 | Inspect the generator for the following conditions:
Are the electrical connections pulling on the generator or are any hoses, etc. resting on the generator? | -- | ||||||
9 |
Has the noise decreased or stopped? | -- | System OK | |||||
10 | Check the drive belt for proper tension. Refer to Drive Belt Tensioner Diagnosis in Engine Mechanical. Is the drive belt loose? | -- | ||||||
11 |
Has the noise decreased or stopped? | -- | System OK | |||||
12 | Compare the vehicle with a known good vehicle. Do both vehicles make the same noise? | -- | System OK | |||||
13 |
Important: If no definite generator problems were found, be sure that all other possible sources of objectionable noise are eliminated before replacing the generator. Replacing the generator may not change the noise level if the noise is a normal characteristic of the generator or the generator mounting. Replace the generator. Refer to Generator Replacement . Has the noise decreased or stopped? | -- | System OK | -- |