Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
- Disconnect
the battery negative cable.
- Install the male end of
the J 38758
to the battery
negative terminal.
- Turn OFF the test switch.
- Install the battery negative cable to the female end of the test
switch.
- Install the Scan Tool
(or equivalent) or wait for 20 minutes.
Notice: Do not turn the parasitic draw test switch to the OFF position with
the engine running. Damage will occur to the vehicle's electrical system.
- Turn ON the test switch.
- Road test the vehicle while activating all accessories, including
the radio and the air conditioning.
- Lower the door glass, then exit the vehicle. Do not move the door
handle after closing the door.
- Open the hood.
- Turn OFF the ignition switch. Remove the key.
Important: From this point on, electrical continuity must be maintained in the
ground circuit of the battery through the parasitic draw test switch J 38758
in the ON position or
through the ammeter J 39200
.
- Components such as the VCM have timers that draw several amps of current
while they cycle down. This can give a false parasitic drain reading. Wait
20 minutes for these components to power down before continuing this
test.
- Connect a jumper wire with a 10 A fuse J 36169-A
to the terminals of the test switch.
- Turn the test switch to the OFF position.
- Wait ten seconds.
If the fuse does not blow, the current is less than 10 A.
The ammeter can be used safely.
- Before the fused jumper wire is removed, turn the test switch
to the ON position.
- You can detect a high current drain using the following procedure:
| Important: If an ammeter other than the J 39200
is used, ensure that the vehicle does not have a high current
drain that would damage the ammeter when connected to the circuit.
|
16.1. | Set the ammeter J 39200
to the 10 A scale. |
16.2. | Connect the ammeter to the test switch terminals. |
16.3. | Turn OFF the test switch. This allows the current to flow through
the ammeter. |
16.4. | Wait one minute, then check the current reading. |
• | When there is a current reading of 2 A or less, turn ON
the test switch, this maintains continuity in the electrical system. |
• | Then, switch the meter down to the 2 A scale, for a more
accurate reading, when the test switch is reopened. |
- Open the test switch.
- Take the reading in milliamps.
- Note the battery reserve capacity. Refer to
Battery Usage
.
• | Divide this number by 4. Example: 90/4 = 22.5 |
• | Compare this to the ammeter reading. |
• | The current drain in milliamps should not exceed this number. |
• | Example: if a battery has a reserve capacity of 90 minutes, the
current drain should not exceed 22 milliamps. |
Notice: The test switch must be in the ON position when removing the fuses in
order to maintain continuity in the electrical system. This avoids damaging
the digital multimeter due to accidental overloading, such as
a door being opened to change a fuse.
- When the current draw is too high, remove the electrical system fuses
one at a time until the draw returns to a value less than or equal to
specifications.
• | Start with the fuses that are hot all the time. |
• | To remove the fuse, you must first open the door, which causes
a high enough current flow to damage the ammeter. |
• | Protect the ammeter, without disturbing the electrical continuity,
by turning ON the test tool before opening the door. |
• | Remove the courtesy lamp fuse. |
• | Note the ammeter reading. |
• | If the parasitic load is still excessive, start removing the remaining
fuses one at a time. |
• | Keep the courtesy lamp fuse out during diagnosis, so the door
can remain open. |
• | Perform Steps 11 through 13 each time a fuse is removed. |
- Removing the VCM fuse should cause a drop of less than 10 milliamps.
A drop greater than 10 milliamps indicates a possible short to
ground.
- Check the orange wires along with the components connected to
the orange wires.
No drop in the milliampere reading indicates the VCM is not drawing
current.
- Repeat the parasitic current drain test procedure after any repair
has been completed.
- When the cause of the excessive current draw has been located
and repaired, remove the ammeter and the parasitic draw test switch.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Connect the battery
negative cable.
Tighten
Tighten the battery negative cable bolt to 15 N·m (11 lb ft).