Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Interior Lamps System Check? | -- | Go to Step 2 | |
2 | Connect a test lamp J 35616-200 from CKT 40 (ORN) cavity A of the inoperative vanity lamp to ground. Does the test lamp light? | -- | Go to Step 3 | Go to Step 4 |
3 | Repair the open in CKT 750 (BLK) between the vanity lamp and ground G110. Is the repair complete? | -- | -- | |
4 | Repair the open in CKT 40 (ORN) to the vanity lamp to splice S220. Is the repair complete? | -- | -- |