The numbers below refer to the step numbers on the diagnostic table.
This step tests for auxiliary heater and A/C blower motor operation in any speed setting.
This step identifies the presence of battery positive voltage at the auxiliary heater and A/C blower motor switches.
This step tests for a possible open in the A/C relay ground circuit.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The auxiliary blower motor is inoperative in all speed positions. | |||
1 | Did you review the rear Heat or A/C operation and perform the necessary inspections? | Go to Step 2 | |
Does the auxiliary heater blower motor or auxiliary A/C blower motor operate in each speed position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | |
Connect a test lamp between the auxiliary HVAC switch supply voltage circuit and a known good ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did the test lamp illuminate? | Go to Step 8 | Go to Step 4 | |
4 | Test the A/C relay coil ignition 3 circuit for an open or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 5 |
5 | Test the A/C relay battery positive voltage circuit for an open or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 6 |
Connect a test lamp between the A/C relay ignition 3 circuit and the ground circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Does the test lamp illuminate? | Go to Step 13 | Go to Step 7 | |
7 | Repair an open in the A/C relay ground circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | -- |
8 |
Does the test lamp illuminate and change intensity for each position? | Go to Step 9 | Go to Step 11 |
9 |
Does the test lamp illuminate and change intensity for each position? | Go to Step 16 | Go to Step 10 |
10 | Test the blower motor ground circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | -- |
11 |
Important: The auxiliary blower motor switch must be in the correct speed position for the blower motor speed circuit being tested. Failure to do this will result in a misdiagnosis.
Does the test lamp illuminate for each speed position? | Go to Step 15 | Go to Step 12 |
12 | Test the appropriate auxiliary speed control circuit for an open or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 14 |
13 | Inspect for poor connections at the harness connector of the A/C relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 17 |
14 | Inspect for poor connections at the harness connector of the auxiliary blower motor switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 18 |
15 | Inspect for poor connections at the harness connector of the auxiliary blower motor resistor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 19 |
16 | Inspect for poor connections at the harness connector of the auxiliary blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 20 |
17 | Replace the A/C relay. Did you complete the replacement? | Go to Step 21 | -- |
18 | Replace the appropriate auxiliary blower motor switch. Refer to Heater and Air Conditioning Control Blower Switch Replacement or Heater Control Blower Switch Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 21 | -- |
19 | Replace the appropriate auxiliary blower motor resistor. Refer to Auxiliary Air Conditioning Blower Motor Resistor Replacement or Auxiliary Heater Blower Motor Resistor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 21 | -- |
20 | Replace the appropriate auxiliary blower motor. Refer to Auxiliary Blower Motor Replacement or Auxiliary Air Conditioning Blower Motor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 21 | -- |
21 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |