The HVAC Scan Tool Data Definitions contains a brief description
of all HVAC related parameters available on the scan tool. The list is in
alphabetical order. A given parameter may appear in any one of the data lists.
In some cases, the parameter may appear more than once or in more than one
data list in order to group certain related parameters together. All parameters
may not apply to every vehicle. Use only the parameters which apply to your
particular vehicle.
A/C Evaporator Switch: The scan tool displays Open or Closed. The A/C evaporator switch
is an input to the PCM that determines when pressure has reached a calibrated
threshold. The PCM uses this switch as the primary input for determining when
to command the A/C compressor ON or OFF.
A/C Sec. High Pressure Switch: The scan tool displays Open or Closed. The secondary high pressure
switch closes when the A/C system's high pressure limit is approached. The
PCM monitors the state of this switch for compressor and auto recirculation
operation. The switch closes at a high pressure value which is calibrated
for specific platforms. The PCM continuously monitors the secondary high pressure
switch when A/C has been selected by the operator.
A/C Relay: The scan tool displays On or Off. On is displayed when the PCM
has energized the A/C compressor clutch relay.
A/C Request: The scan tool displays Yes or No. The PCM uses the A/C request
signal in order to determine whether A/C compressor operation has been requested
by the operator.
HVAC Switch In Recirculation Mode: The scan tool displays Yes or No. The PCM uses this information
to control A/C compressor clutch cycling.