The number below refers to the step number on the diagnostic table.
Step | Action | Values | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the heating is insufficient. | ||||||||||||||||
1 | Did you review the HVAC operation and perform the necessary inspections? | -- | Go to Step 2 | |||||||||||||
2 |
Does the blower motor operate at all? | -- | Go to Step 3 | Go to Blower Motor Inoperative | ||||||||||||
3 | Does the blower motor operate in each speed position? | -- | Go to Step 4 | Go to Blower Motor Malfunction | ||||||||||||
4 | Alternately place the recirculation door between MAX A/C and VENT. Does the recirculation door operate properly? | -- | Go to Step 5 | Go to Air Delivery Improper | ||||||||||||
5 | Inspect the cooling system for the following conditions:
Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 6 | ||||||||||||
6 |
Does the air conditioning (A/C) compressor operate? | -- | Go to Step 7 | |||||||||||||
7 |
Does the air temperature actuator drive shaft rotate at all? | -- | Go to Step 8 | Go to Step 9 | ||||||||||||
8 | Inspect the air temperature door and the air temperature actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 18 | Go to Heating Performance Diagnostic in Heating, Ventilation and Air Conditioning | ||||||||||||
9 | Test the ignition 3 voltage circuit of the air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 10 | ||||||||||||
10 | Test the ground circuit of the air temperature actuator for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 11 | ||||||||||||
11 | Test the air temperature door control signal circuit of the air temperature actuator for an open, high resistance, short to ground, or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 12 | ||||||||||||
Important: Ensure that the HVAC control assembly connector is connected during this test in order to avoid misdiagnosis.
Does the voltage measure within the specified values with a smooth transition between cold and hot? |
| Go to Step 13 | Go to Step 15 | |||||||||||||
13 | Inspect for poor connections at the harness connector of the air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 14 | ||||||||||||
14 | Inspect the air temperature actuator, door, and any attaching linkage for binding or a condition that prevents drive shaft rotation. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 16 | ||||||||||||
15 | Inspect for poor connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 17 | ||||||||||||
16 | Replace the air temperature actuator. Refer to Air Temperature Actuator Replacement . Did you complete the replacement? | -- | Go to Step 18 | -- | ||||||||||||
17 | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | -- | Go to Step 18 | -- | ||||||||||||
18 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |