Tools Required
Notice: Never operate the starter motor more than 15 seconds at a time without
pausing in order to allow it to cool for at least 2 minutes. Overheating will
damage the starter motor.
Important: Verify that the battery is in good condition.
Refer to
Battery Load Test
.
- Disable the fuel system. Refer to Engine Controls.
- Calculate the current
draw.
2.1. | Select the 200 amp or the 2000 amp scale on the J 35590
. |
2.2. | Zero the current clamp. |
2.3. | Clamp the current clamp to the battery negative cable. |
2.4. | Crank the engine and observe the meter readings. The reading should
be 330-360 amps. |
• | If the amperage is over 360, an internal starter failure may be
the cause. |
• | If the amperage is under 330, a battery cable or connection may
be the cause. |