Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did the Auxiliary Power Outlets System Check bring you here? | -- | Go to Step 2 | |
2 | Inspect the cigar lighter fuse 13 at I/P fuse block. Is the fuse functional? | -- | Go to Step 4 | Go to Step 3 |
3 | Locate and repair the overload in circuit 640 and replace the cigar lighter fuse. Is the repair complete? | -- | -- | |
4 |
Does the test lamp light? | -- | Go to Step 6 | Go to Step 5 |
5 | Repair the open in CKT 640 between the instrument panel fuse block and the cigarette lighter. Is the repair complete? | -- | -- | |
6 | Inspect for an open in CKT 1050 (BLK) between the cigarette lighter and ground G200. Did you find an open? | -- | Go to Step 7 | Go to Step 8 |
7 | Repair the open in CKT 1050 (BLK) between the cigarette lighter and ground G200. Is the repair complete? | -- | -- | |
8 | Replace the cigarette lighter. Is the replacement complete? | -- | -- |