Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Defogger System Check? | -- | Go to Step 2 | Go to Defogger System Check . |
2 |
Is the repair complete | -- | Go to Defogger System Check | -- |
3 | Replace the HVAC control module. Is the repair complete? | -- | Go to Defogger System Check | Go to Step 4 |
4 |
Is there continuity between the components? | -- | Go to Step 6 | Go to Step 5 |
5 | Locate and repair an open in CKT 293 (PPL) between the HVAC control module connector and the rear defogger grid. Is the repair complete? | -- | Go to Defogger System Check | -- |
6 |
Is there continuity between the components? | -- | Go to Step 7 | Go to Step 8 |
7 | Repair the defogger grid(s) as needed. Is the repair complete? | -- | Go to Defogger System Check | -- |
8 | Locate and repair an open in CKT 1450 (BLK) between the rear defogger grid ground connector and G403. Is the repair complete? | -- | Go to Defogger System Check | -- |