Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Locks System Check? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 6 |
3 | Is the lock function inoperative by the liftgate lock/unlock switch? | -- | Go to Step 5 | Go to Step 4 |
4 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 6 |
5 | Repair the open in CKT 195 (LT BLU) between the liftgate lock/unlock release switch and splice S232. Is the repair complete? | -- | -- | |
6 | Use a test lampJ 35616-200 in order to backprobe CKT 640 (ORN) cavity D at the liftgate lock/unlock release switch to ground. Does the test lamp light? | -- | Go to Step 8 | Go to Step 9 |
7 | Repair the open in CKT 194 (WHT) between the liftgate lock/unlock release switch and splice S231. Is the repair complete? | -- | -- | |
8 | Replace the liftgate lock/unlock release switch. Is the repair complete? | -- | -- | |
9 | Repair the open in CKT 640 (ORN) between the instrument panel fuse block and the liftgate lock/unlock release switch. Is the repair complete? | -- | -- |