Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify the fault is present. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Important: There is a flat band in the gauge where the engine temp is between 190°F (88°C) and 220°F (104°C) and gauge stays at 200°F (93°C).
Is the temperature on the scan tool and the temperature on the gauge approximately the same outside the flat band? | Approximately 200°F (93°C) @ steady state | Go to Step 4 | Go to Step 5 |
4 |
Does the gauge reading properly? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 5 |
5 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Did you complete the replacement? | -- | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |