Disassembly Procedure
- Drain the oil from the reservoir (1).
- Remove the connector and fitting assembly (2).
- Remove the control valve assembly (4) from the pump housing (1). Make sure the flow control spring (5) does not fall out of the pump housing (1).
- Remove and discard the O-ring seal (3) from the connector and fitting assembly (2).
Assembly Procedure
- Install the flow control spring (5), if removed from the pump housing (1).
- Lubricate the new O-ring seal (3) with power steering fluid.
- Install the O-ring seal (3) onto the connector and fitting assembly (2).
- Install the control valve assembly (4).
Notice: Refer to Fastener Notice in the Preface section.
- Install the connector and fitting assembly (2).
Tighten
Tighten the connector and fitting assembly to 75 N·m (55 lb ft).