Table 1: | A/C Performance Table with Aux A/C |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient air temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low and high side pressures within the specified value? |
| Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual or |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Discharge Air Temperature | ||
---|---|---|---|---|---|
Low Side | High Side | Left Front Center | Left Rear | ||
13-18°C (55-65°F) | 0-100% | 151-220 kPa (22-32 psi) | 537-937 kPa (78-136 psi) | 5°C (41°F) | 7°C (45°F) |
19-24°C (66-75°F) | Below 40% | 151-248 kPa (22-36 psi) | 689-1109 kPa (100-161 psi) | 8°C (46°F) | 10°C (50°F) |
Above 40% | 151-282 kPa (22-41 psi) | 757-1178 kPa (110-171 psi) | 10°C (50°F) | 12°C (54°F) | |
25-29°C (76-85°F) | Below 35% | 186-289 kPa (27-42 psi) | 978-1322 kPa (142-192 psi) | 11°C (52°F) | 13°C (55°F) |
35-50% | 206-303 kPa (30-44 psi) | 1019-1336 kPa (148-194 psi) | 12°C 54°F) | 14°C (57°F) | |
Above 50% | 213-323 kPa (31-47 psi) | 1040-1378 kPa (151-200 psi) | 14°C (57°F) | 16°C (61°F) | |
30-35°C (86-95°F) | Below 30% | 234-337 kPa (34-49 psi) | 1212-1577 kPa (176-229 psi) | 15°C (59°F) | 18°C (64°F) |
30-50% | 248-351 kPa (36-51 psi) | 1233-1598 kPa (179-232 psi) | 17°C (63°F) | 19°C (66°F) | |
Above 50% | 261-372 kPa (38-54 psi) | 1260-1619 kPa (183-235 psi) | 19°C (66°F) | 21°C (70°F) | |
36-41°C (96-105°F) | Below 20% | 289-385 kPa (42-56 psi) | 1488-1853 kPa (216-269 psi) | 19°C (66°F) | 21°C (70°F) |
20-40% | 296-399 kPa (43-58 psi) | 1488-1853 kPa (216-269 psi) | 21°C (70°F) | 23°C (73°F) | |
Above 40% | 310-413 kPa (45-60 psi) | 1508-1853 kPa (219-269 psi) | 22°C (72°F) | 24°C (75°F) | |
42-46°C (106-115°F) | Below 20% | 344-434 kPa (50-63 psi) | 1770-2080 kPa (257-302 psi) | 23°C (73°F) | 25°C (77°F) |
Above 20% | 351-447 kPa (51-65 psi) | 1770-2067 kPa (257-300 psi) | 24°C (75°F) | 27°C (81°F) | |
47-49°C (116-120°F) | Below 30% | 392-482 kPa (57-70 psi) | 1998-2301 kPa (290-334 psi) | 27°C (81°F) | 28°C (82°F) |
Table 1: | A/C Performance Table with Aux A/C |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient air temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low and high side pressures within the specified value? |
| Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual or |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Discharge Air Temperature | ||
---|---|---|---|---|---|
Low Side | High Side | Left Front Center | Left Rear | ||
13-18°C (55-65°F) | 0-100% | 151-220 kPa (22-32 psi) | 489-923 kPa (71-134 psi) | 7°C (41°F) | 10°C (45°F) |
19-24°C (66-75°F) | Below 40% | 151-234 kPa (22-34 psi) |
578-1019 kPa (84-148 psi) | 8°C (46°F) | 12°C (52°F) |
Above 40% | 151-275 kPa (22-40 psi) | 689-1129 kPa (100-164 psi) | 10°C (50°F) | 13°C (55°F) | |
25-29°C (76-85°F) | Below 35% | 172-275 kPa (25-40 psi) | 868-1219 kPa (126-177 psi) | 10°C (50°F) | 14°C (57°F) |
35-50% | 192-389 kPa (28-42 psi) | 930-1336 kPa (148-194 psi) | 12°C 54°F) | 14°C (57°F) | |
Above 50% | 206-310 kPa (30-45 psi) | 971-1302 kPa (141-189 psi) | 13°C (55°F) | 18°C (63°F) | |
30-35°C (86-95°F) | Below 30% | 220-323 kPa (32-47 psi) | 1102-1460 kPa (160-212 psi) | 14°C (57°F) | 18°C (64°F) |
30-50% | 234-337 kPa (34-49 psi) | 1129-1481 kPa (164-215 psi) | 15°C (59°F) | 19°C (66°F) | |
Above 50% | 248-358 kPa (36-52 psi) | 1157-1502 kPa (168-218 psi) | 18°C (64°F) | 20°C (68°F) | |
36-41°C (96-105°F) | Below 20% | 275-378 kPa (40-55 psi) | 1371-1722 kPa (199-250 psi) | 18°C (64°F) | 23°C (73°F) |
20-40% | 282-385 kPa (41-56 psi) | 1378-1722 kPa (200-250 psi) | 19°C (66°F) | 23°C (73°F) | |
Above 40% | 296-392 kPa (43-57 psi) | 1391-1708 kPa (202-248 psi) | 20°C (68°F) | 24°C (75°F) | |
42-46°C (106-115°F) | Below 20% | 330-420 kPa (48-61 psi) | 1639-1942 kPa (238-282 psi) | 22°C (70°F) | 27°C (79°F) |
Above 20% | 337-427 kPa (49-62 psi) | 1639-1922 kPa (238-279 psi) | 23°C (72°F) | 27°C (79°F) | |
47-49°C (116-120°F) | Below 30% | 385-468 kPa (56-68 psi) | 1860-2149 kPa (270-312 psi) | 25°C (77°F) | 28°C (82°F) |
Table 1: | A/C Performance Table with Aux A/C |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient air temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low and high side pressures within the specified value? |
| Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual or |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Discharge Air Temperature | ||
---|---|---|---|---|---|
Low Side | High Side | Left Front Center | Left Rear | ||
13-18°C (55-65°F) | 0-100% | 151-268 kPa (22-39 psi) | 819-1350 kPa (119-196 psi) | 12°C (52°F) | 15°C (59°F) |
19-24°C (66-75°F) | Below 40% | 172-310 kPa (25-45 psi) | 999-1550 kPa (145-225 psi) | 14°C (57°F) | 17°C (61°F) |
Above 40% | 199-344 kPa (29-50 psi) | 1123-1681 kPa (163-244 psi) | 17°C (61°F) | 19°C (66°F) | |
25-29°C (76-85°F) | Below 35% | 248-358 kPa (36-52 psi) | 1391-1832 kPa (202-266 psi) | 18°C (63°F) | 20°C (68°F) |
35-50% | 261-372 kPa (38-54 psi) | 1460-1867 kPa (212-271 psi) | 18°C 64°F) | 22°C (70°F) | |
Above 50% | 275-392 kPa (40-57 psi) | 1508-1949 kPa (219-283 psi) | 19°C (66°F) | 23°C (72°F) | |
30-35°C (86-95°F) | Below 30% | 303-420 kPa (44-61 psi) | 1701-2177 kPa (247-316 psi) | 22°C (70°F) | 25°C (77°F) |
30-50% | 316-434 kPa (46-63 psi) | 1743-2218 kPa (253-322 psi) | 23°C (73°F) | 25°C (77°F) | |
Above 50% | 330-454 kPa (48-66 psi) | 1791-2280 kPa (260-331 psi) | 24°C (75°F) | 27°C (79°F) | |
36-41°C (96-105°F) | Below 20% | 365-482 kPa (53-70 psi) | 2060-2528 kPa (299-367 psi) | 25°C (77°F) | 30°C (86°F) |
20-40% | 372-496 kPa (54-72 psi) | 2080-2563 kPa (302-372 psi) | 28°C (81°F) | 30°C (86°F) | |
Above 40% | 385-502 kPa (56-73 psi) | 2122-2576 kPa (308-374 psi) | 28°C (82°F) | 30°C (86°F) | |
42-46°C (106-115°F) | Below 20% | 440-544 kPa (64-79 psi) | 2439-2838 kPa (354-412 psi) | 29°C (84°F) | 34°C (93°F) |
Above 20% | 440-551 kPa (64-80 psi) | 2452-2852 kPa (356-414 psi) | 30°C (86°F) | 34°C (93°F) | |
47-49°C (116-120°F) | Below 30% | 502-599 kPa (73-87 psi) | 2762-3141 kPa (401-456 psi) | 34°C (93°F) | 41°C (105°F) |
Table 1: | A/C Performance Table with Aux A/C |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient air temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low and high side pressures within the specified value? |
| Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual or |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Discharge Air Temperature | ||
---|---|---|---|---|---|
Low Side | High Side | Left Front Center | Left Rear | ||
13-18°C (55-65°F) | 0-100% | 179-268 kPa (26-39 psi) | 682-999 kPa (99-145 psi) | 11°C (51°F) | 13°C (54°F) |
19-24°C (66-75°F) | Below 40% | 199-289 kPa (29-42 psi) | 813-1157 kPa (118-168 psi) | 14°C (56°F) | 15°C (59°F) |
Above 40% | 206-3102 kPa (30-45 psi) | 861-1191 kPa (125-173 psi) | 14°C (56°F) | 15°C (59°F) | |
25-29°C (76-85°F) | Below 35% | 234-316 kPa (34-46 psi) | 1061-1350 kPa (154-196 psi) | 17°C (61°F) | 18°C (64°F) |
35-50% | 248-323 kPa (36-47 psi) | 1081-1350 kPa (157-196 psi) | 18°C (64°F) | 18°C (64°F) | |
Above 50% | 254-344 kPa (37-50 psi) | 1088-1350 kPa (158-196 psi) | 18°C (64°F) | 19°C (66°F) | |
30-35°C (86-95°F) | Below 30% | 261-351 kPa (38-51 psi) | 1260-1577 kPa (183-229 psi) | 19°C (65°F) | 22°C (70°F) |
30-50% | 268-365 kPa (39-53 psi) | 1267-1557 kPa (184-226 psi) | 19°C (66°F) | 23°C (72°F) | |
Above 50% | 282-385 kPa (41-56 psi) | 1267-1543 kPa (184-224 psi) | 20°C (68°F) | 23°C (73°F) | |
36-41°C (96-105°F) | Below 20% | 296-378 kPa (43-55 psi) | 1508-1818 kPa (219-264 psi) | 20°C (68°F) | 23°C (73°F) |
20-40% | 303-392 kPa (44-57 psi) | 1502-1791 kPa (218-260 psi) | 22°C (70°F) | 25°C (77°F) | |
Above 40% | 316-406 kPa (46-59 psi) | 1488-1756 kPa (216-255 psi) | 23°C (72°F) | 27°C (79°F) | |
42-46°C (106-115°F) | Below 20% | 330-406 kPa (48-59 psi) | 1756-2018 kPa (255-293 psi) | 23°C (72°F) | 27°C (79°F) |
Above 20% | 337-420 kPa (49-61 psi) | 1743-1970 kPa (253-286 psi) | 24°C (75°F) | 28°C (82°F) | |
47-49°C (116-120°F) | Below 30% | 365-447 kPa (53-65 psi) | 1942-2191 kPa (282-318 psi) | 25°C (77°F) | 30°C (86°F) |