The inside air temperature sensor assembly allows the HVAC control module to monitor the temperature of the air inside the passenger compartment. The module applies 5 volts to internal input resistor that is connected to the signal circuit of the air temperature sensor. The module provides ground to the air temperature sensor through the low reference circuit. The HVAC control module monitors the voltage drop across the air temperature sensor and uses the input for automatic control calculations. When the air temperature is cold, the resistance of the sensor is high and the voltage signal is high. When the air temperature is hot, the resistances of the sensor is low and the voltage signal is low.
• | Battery voltage to the HVAC control module is greater than 8.7 V and less than 16.5 V. |
• | The ignition is turned ON. |
The HVAC control module determines that the voltage applied to the input for the air temperature sensor is less than 0.09 V or greater than 4.9 V.
The HVAC control module use a default value of 25°C (77°F) for the Inside Air Temp. parameter. This value will be displayed on the scan tool.
• | The DTC will become history if the HVAC control module no longer detects the condition that set the DTC. |
• | The history DTC will clear after 100 fault-free ignition cycles. |
• | The DTC can be cleared with a scan tool. |
The number below refers to the step number on the diagnostic table.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views | ||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |
Does the scan tool indicate that B0164 is a current DTC? | -- | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | |
3 |
Does the voltage measure near the specified value? | 5 V | Go to Step 4 | Go to Step 5 |
4 | Measure the voltage from the signal circuit to the low reference circuit of the inside air temperature sensor. Does the voltage measure near the specified value? | 5 V | Go to Step 7 | Go to Step 6 |
5 | Test the signal circuit of the inside air temperature sensor for an open, high resistance, short to ground, or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 8 |
6 | Test the low reference circuit of the inside air temperature sensor for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 8 |
7 | Inspect for poor connections at the harness connector of the inside air temperature sensor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 9 |
8 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 10 |
9 | Replace the inside air temperature sensor assembly. Refer to Inside Air Temperature Sensor Replacement . Did you complete the replacement? | -- | Go to Step 11 | -- |
10 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 11 | -- |
11 |
Does the DTC reset? | -- | Go to Step 2 | System OK |