GM Service Manual Online
For 1990-2009 cars only

Instrument Panel Cluster (IPC) Gauges Inoperative (Reprogram IPC)

Subject:Instrument Panel Cluster (IPC) Gauges Inoperative (Reprogram IPC)

Models:2003 Cadillac Escalade, Escalade ESV, Escalade EXT
2003 Chevrolet Avalanche, Silverado, Suburban, Tahoe
2003 GMC Sierra, Yukon, Yukon XL



Condition

Some customers may comment that upon vehicle start-up, all instrument panel cluster gauges are inoperative.

Cause

During a cold start or low battery condition, a low voltage condition may cause gauges to freeze during crank cycle.

Correction

Important: DO NOT REPLACE the following clusters unless a reprogram does not correct this condition.

   • 15182138
   • 15182139
   • 15182140
   • 15182141
   • 15182142
   • 15182143
   • 15182144
   • 15182145
   • 15182146
   • 15182147
   • 15182148
   • 15182149
   • 15182150
   • 15182151
   • 15182152
   • 15182153
   • 15182154
   • 15182155
   • 15182156
   • 15182157
   • 15177467
   • 15177468

A new service calibration has been released to correct this condition. Reprogram the IPC using the new service calibration, which was available from Techline starting November 3, 2003 on the TIS2000 version 11.5 or later. This calibration is an electronic calibration and is not available from GMSPO.

Warranty Information

For vehicles repaired under warranty, use:

Labor Operation

Description

Labor Time

N4199

Instrument Panel Cluster (IPC) Module - Reprogram

0.4 hr