Important: When replacing a theft deterrent control module with a GM Service Parts
Operation (SPO) Replacement Part, the procedure to setup a new theft deterrent
control module must be performed prior to the 10 Minute Re-Learn
Procedure.
Tools Required
Tech 2 diagnostic scan tool
Procedure to setup a New Theft Deterrent Control Module
Use this procedure only if replacing the theft deterrent control module
with a GM Service Parts Operation (SPO) Replacement Part.
- Connect the Tech 2 diagnostic scan tool to the vehicle.
- Turn ON the ignition , with the engine OFF.
- With the scan tool, select Setup New VTD Module in the Vehicle
Theft Deterrent, Special Functions data list.
- Follow the scan tool on screen instructions.
Important:
• | When replacing a theft deterrent control module with a GM Service
Parts Operation (SPO) Replacement Part, the module will learn keys immediately.
The existing PCM however, must learn the new fuel continue password
when the theft deterrent control module is replaced. |
• | When replacing a powertrain control module (PCM) with a GM Service
Parts Operation (SPO) Replacement Part, after programming, these modules
will learn the incoming fuel continue password immediately upon
receipt of a password message. Once a password message is received,
and a password is learned, a relearn procedure must be performed
to change this password again. A PCM which has been previously
installed in another vehicle will have learned the fuel continue password
of the other vehicles theft deterrent control module and will require performing
the 10 Minute Re-Learn Procedure to learn the fuel continue
password of the current vehicles theft deterrent control modules . |
• | When performing the 10 Minute Re-Learn Procedure, all previously
learned keys will be erased from the theft deterrent control module's
memory. |
• | Additional keys may be learned immediately after the 10 Minute
Re-Learn Procedure. Refer to
Adding Keys
. |
• | When performing the 10 Minute Re-Learn Procedure, 2 master
passkey III+ (PK3+) keys are required. If a gray valet key is learned
first, the theft deterrent control module will not allow additional keys
to be learned. |
Tools Required
• | Tech 2 diagnostic scan tool |
• | Techline Terminal with current Service Programing System (SPS)
software |
10 Minute Re-Learn Procedure
Use this procedure after replacing any of the following components:
• | The passkey III+ (PK3+) keys |
• | The theft deterrent control module |
• | The PCM, see Important above |
Important: If replacing a theft deterrent control module with a GM Service Parts
Operation (SPO) Replacement Part, insure the procedure to setup a new theft
deterrent control module has been performed prior to the 10 Minute
Re-Learn Procedure.
- Connect the Tech 2 diagnostic scan tool to the vehicle.
- With the scan tool, select Request Info. under Service Programing
System and follow the scan tool on screen instructions.
- Disconnect the scan tool from the vehicle and connect it to a
Techline Terminal with current Service Programing System (SPS) software.
- On the Techline Terminal, select Service Programming Systems and
follow the Techline Terminal on screen instructions.
- Disconnect the scan tool from the Techline Terminal and re-connect
it to the vehicle.
- With a master passkey III+ (PK3+) key, turn ON the ignition,
with the engine OFF.
- With the scan tool, select Program ECU under Service Programing
System.
- At this point the scan tool must remain connected for the duration
of the 10 Minute Re-Learn Procedure.
- Observe the SECURITY telltale or the scan tool on screen timer,
after approximately 10 minutes the scan tool timer will expire and/or
the telltale will turn off. The vehicle is now ready to relearn the key information
and/or passwords on the next ignition switch transition from OFF to CRANK.
- Turn OFF the ignition and wait 5 seconds.
- With a master passkey III+ (PK3+) key, start the vehicle, the
theft deterrent control module has now learned the key transponder information
and the PCM has now learned the fuel continue password.
- Turn OFF the ignition and wait 15 seconds minimum.
- With a second master passkey III+ (PK3+) key, start the vehicle,
the theft deterrent control module has now learned the second master passkey
III+ (PK3+) key transponder information.
- Learning Additional keys, if required. Refer to
Adding Keys
.
- With the scan tool, clear any DTCs.