Checks | Cause |
---|---|
TCC Circuit | Blockage during apply or release |
TCC Valve Spring (224) | The spring is broken. |
Pump Cover (206) | Cross channel leakage |
Pressure Regulator Valve (231) | The valve is stuck in a high demand position. |
Oil Cooler | The cooler or the cooler lines are blocked. |
Gasket (6) | The gasket is damaged. |
Retainer Pin (211) | The pin is broken. |
Turbine Shaft O-ring (2) | The O-ring is damaged. |
Turbine Shaft Seals (503) | The seals are damaged. |
Stator Shaft Bushing (233) | The bushing is worn or damaged. |
Oil Transfer Hole Cup Plug | The plug is leaking. |
Fluid | The fluid level is low. |
Radiator | Air flow is restricted. |