The number(s) below refer to the step number(s) on the diagnostic table.
This step tests for auxiliary blower motor operation in the OFF setting.
The rear auxiliary HVAC control assembly should not operate with the front auxiliary blower motor switch in the OFF position.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The auxiliary blower motor is on while the auxiliary blower motor switch is in the OFF position. | |||
1 | Did you review the auxiliary HVAC operation and perform the necessary inspections? | Go to Step 2 | |
Does the auxiliary blower motor operate? | Go to Step 4 | Go to Step 3 | |
Important: The front auxiliary blower motor switch must remain in the OFF position. Place the rear auxiliary blower motor switch to the maximum speed position. Does the auxiliary blower motor operate? | Go to Step 8 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | |
4 |
Does the auxiliary blower motor continue to operate? | Go to Step 5 | Go to Step 6 |
5 | Test each auxiliary blower motor speed control circuit between the auxiliary blower motor resistor assembly and the rear auxiliary HVAC control assembly for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 11 |
6 |
Does the auxiliary blower motor operate? | Go to Step 7 | Go to Step 13 |
7 | Test each auxiliary blower motor speed control circuit between the front auxiliary HVAC control assembly and the rear auxiliary HVAC control assembly for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 12 |
8 |
Does the auxiliary blower motor continue to operate? | Go to Step 9 | Go to Step 13 |
9 | Test the rear auxiliary enable control circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 10 |
10 | Test auxiliary blower motor control circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 14 |
11 | Inspect for poor connections at the harness connector of the auxiliary blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 16 |
12 | Inspect for poor connections at the harness connector of the rear auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 17 |
13 | Inspect for poor connections at the harness connector of the front auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 15 |
14 | Inspect for poor connections at the harness connector of the auxiliary HVAC control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 18 |
15 | Replace the front auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the replacement? | Go to Step 19 | -- |
16 | Replace the auxiliary blower motor resistor assembly. Refer to Auxiliary Blower Motor Resistor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 19 | -- |
17 | Replace the rear auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Rear . Did you complete the replacement? | Go to Step 19 | -- |
18 | Replace the auxiliary HVAC control processor. Refer to Auxiliary HVAC Control Processor Replacement . Did you complete the replacement? | Go to Step 19 | -- |
19 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |