The numbers below refer to the step numbers on the diagnostic table.
This step tests for auxiliary blower motor operation in any speed setting.
This step determines if the malfunction is in the control side of the system.
Test both the rear auxiliary HVAC control assembly chassis ground circuit and the ground circuit between the front and rear HVAC control assemblies.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The auxiliary blower motor is inoperative in all speed positions. | |||
1 | Did you review the auxiliary HVAC operation and perform the necessary inspections? | Go to Step 2 | |
Does the auxiliary blower motor operate in each speed position from both the front and rear blower motor switches? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 6 |
4 | Connect a test lamp between the auxiliary blower motor supply circuit and the auxiliary blower motor ground circuit. Does the test lamp illuminate? | Go to Step 12 | Go to Step 5 |
5 | Test the ground circuit of the auxiliary blower motor resistor assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 13 |
6 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 15 |
7 | Probe the auxiliary blower motor resistor assembly battery positive voltage circuit with a test lamp that is connected to a good ground. Does the test lamp illuminate? | Go to Step 8 | Go to Step 16 |
Does the test lamp illuminate? | Go to Step 13 | Go to Step 9 | |
9 |
Does the test lamp illuminate? | Go to Step 14 | Go to Step 10 |
Test the auxiliary HVAC control assembly ground circuits for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 11 | |
11 | Inspect for poor connections at the harness connector of the rear auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 17 |
12 | Inspect for poor connections at the harness connector of the auxiliary blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 19 |
13 | Inspect for poor connections at the harness connectors of the auxiliary blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 20 |
14 | Inspect for poor connections at the harness connector of the front auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 21 | Go to Step 18 |
15 | Repair the ignition 3 voltage circuit of the auxiliary blower motor resistor assembly. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 21 | -- |
16 | Repair the battery positive voltage circuit of the auxiliary blower motor resistor assembly. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 21 | -- |
17 | Replace rear auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Rear . Did you complete the replacement? | Go to Step 21 | -- |
18 | Replace front auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the replacement? | Go to Step 21 | -- |
19 | Replace auxiliary blower motor. Refer to Auxiliary Blower Motor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 21 | -- |
20 | Replace auxiliary blower motor resistor assembly. Refer to Auxiliary Blower Motor Resistor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 21 | -- |
21 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |