The numbers below refer to the step numbers on the diagnostic table.
This step tests for auxiliary blower motor operation in the OFF setting.
The Blower Motor Test parameter must be commanded ON before an OFF command will function.
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The auxiliary blower motor is ON while the auxiliary HVAC controls are in the OFF position. | ||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Automatic in Wiring Systems | ||||||
Does the auxiliary blower motor operate? | -- | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | |||||||
Does the scan tool indicate that the Blower Motor PWM parameter is at 0 %? | -- | Go to Step 4 | Go to Step 14 | |||||||
4 |
Does the scan tool indicate that each parameter is 0? | -- | Go to Step 7 | Go to Step 5 | ||||||
5 | With a scan tool, observe the following parameters in the Rear Aux. Climate Module Front Aux. Controls data list:
Does the scan tool indicate that each parameter is above 13? | -- | Go to Step 9 | Go to Step 6 | ||||||
6 |
Does the scan tool indicate that Blower Switch Pos. parameter is 15? | -- | Go to Step 13 | Go to Step 11 | ||||||
7 |
Does the voltage measure greater than the specified value? | 4.5 V | Go to Step 14 | Go to Step 8 | ||||||
8 | Test the 5 volt reference circuit of the front auxiliary HVAC control assembly for a short to ground, short to voltage or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 14 | ||||||
9 |
Does the voltage measure greater than the specified value? | 11.5 V | Go to Step 14 | Go to Step 10 | ||||||
10 | Test the low reference circuit of the front auxiliary HVAC control assembly for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 14 | ||||||
11 | Test the auxiliary front blower motor speed signal circuit of the front auxiliary HVAC control assembly for a short to voltage, a short to ground, a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 12 | ||||||
12 |
Does the voltage increase as the auxiliary blower motor switch is rotated to maximum speed? | -- | Go to Step 14 | Go to Step 15 | ||||||
13 | Inspect for poor connections at the harness connector of the auxiliary blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 16 | ||||||
14 | Inspect for poor connections at the harness connector of the auxiliary HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 17 | ||||||
15 | Inspect for poor connections at the harness connector of the front auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 18 | ||||||
16 | Replace the auxiliary blower motor control processor. Refer to Auxiliary Blower Motor Processor Replacement . Did you complete the replacement? | -- | Go to Step 19 | -- | ||||||
17 | Replace the auxiliary HVAC control module. Refer to Auxiliary Heater and Air Conditioning Control Module Replacement . Did you complete the replacement? | -- | Go to Step 19 | -- | ||||||
18 | Replace the front auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the replacement? | -- | Go to Step 19 | -- | ||||||
19 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |