• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
Generator Control Module Temperature Sensor Signal | P0A02 | P0A03 | P0A03 | P0A03 | P0A01 |
Low Reference | -- | P0A03 | P0A03 | P0A03 | P0A01 |
The generator control module temperature sensor is a variable resistor that measures the temperature of the coolant entering the generator control module coolant radiator. The engine control module (ECM) supplies 5 volts to the generator control module temperature signal circuit, and a ground for the generator control module temperature low reference circuit.
• | DTCs P0112, P0113, P0117, P0118, P0101, P0102, P0103, P0A02, P0A03 and P2610 are not set. |
• | The ignition has been OFF for greater than 8 hours. |
• | The temperature difference between the IAT and ECT sensors is less than or equal to 16°C (29°F) at ignition ON. |
• | DTCs P0112 or P0113 are not set. |
• | The engine is running for greater than 10 seconds. |
• | The Intake Air Temperature Sensor (IAT) is greater than 70°C (158°F). |
• | This DTC runs continuously when the above conditions are met. |
• | DTCs P0112 or P0113 are not set. |
• | The engine is running for greater than 10 seconds. |
• | The IAT is greater than -20°C (-04°F). |
• | This DTC runs continuously when the above conditions are met. |
The ECM detects that the temperature difference between the generator control module temperature sensor parameter and the ECT sensor is greater than 30°C (54°F).
The ECM detects that the generator control module temperature sensor parameter is less than -60.5°C (-76.9°F).
The ECM detects that the generator control module temperature sensor parameter is greater than 162°C (323.6°F).
DTCs P0A01, P0A02 and P0A03 are Type B DTCs.
• | The cooling fans will be commanded to high speed. |
• | The DIC will display A/C Inoperative |
• | P0A01 requires that the ECM detect that the temperature difference between the generator control module temperature sensor parameter and the ECT sensor is less than or equal to 16°C (29°F) at ignition ON. |
• | DTCs P0A01, P0A02 and P0A03 are Type B DTCs. |
Control Module References for scan tool information
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit terminal B for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |