Testing for Electrical Intermittents for Chevrolet Aveo 2004
Perform the following procedures while wiggling the harness
from side to side. Continue this at convenient points (about 6 inches apart)
while watching the test equipment.
If the fault is not identified, perform the procedure below using the
MIN MAX feature on the J 39200
DMM. This feature allows you to manipulate the circuit without having
to watch the J 39200
.
The J 39200
will generate
an audible tone when a change is detected.
Important: The J 39200
must
be used in order to perform the following procedure since the J 39200
can monitor current, resistance or
voltage while recording the minimum (MIN), and maximum (MAX) values
measured.
- Connect the J 39200
to both sides of a suspected connector (still connected), or from
one end of a suspected circuit to the other. Refer to
Troubleshooting with a Digital Multimeter
for information on
connecting the J 39200
to
the circuit.
- Set the rotary dial of the J 39200
to the V (AC) or V (DC) position.
- Press the range button of the J 39200
in order to select the desired voltage range.
- Press the MIN MAX button of the J 39200
. The J 39200
displays
100 ms RECORD and emits an audible tone (beep).
Important: The 100 ms RECORD mode is the length of time an input must stay at a
new value in order to record the full change.
- Simulate the condition that is potentially causing the intermittent
connection, either by wiggling the connections or the wiring, test driving,
or performing other operations. Refer to
Inducing Intermittent Fault Conditions
.
- Listen for the audible Min Max Alert which indicates that a new
minimum or maximum value has been recorded.
- Press the MIN MAX button once in order to display the MAX value
and note the value.
- Press the MIN MAX button again in order to display the MIN value
and note the value.
- Determine the difference between the MIN and MAX values.
| • | If the variation between the recorded MIN and MAX voltage values
is 1 volt or greater an intermittent open or high resistance condition
exists. Repair the condition as necessary. |
| • | If the variation between the recorded MIN and MAX voltage values
is less than 1 volt an intermittent open or high resistance condition
does not exist. |