When the ignition switch is turned to ON, the sensing and diagnostic module (SDM) will perform a turn-on test to diagnose critical malfunctions within the SDM itself.
The test ignition and deployment loop voltages are measured to ensure that they are within their normal voltage ranges. The SDM monitors the voltages at the driver low and the passenger low to detect shorts to ground or voltage in the deploy loops.
• | The side air bag sensor wiring of the driver high is shorted to ground. |
• | The side air bag sensor wiring of the driver low is shorted to ground. |
Step | Action | Values | Yes | No |
---|---|---|---|---|
Caution: Refer to Sensing and Diagnostic Module Voltage after Ignition is Turned Off Caution in the Preface section. Caution: Refer to Sensing and Diagnostic Module Handling Caution in the Preface section. | ||||
1 | Perform the Diagnostic System Check - SIR. Is the Diagnostic System Check - SIR complete? | -- | Go to Step 2 | |
2 |
Is the air bag wiring damaged? | -- | Go to Step 4 | Go to Step 3 |
3 | Measure the resistance between the SDM and the high, low terminal of the driver side air bag sensor and the ground. Is the resistance at the specified value? | 10 K ohms | Go to Step 5 | Go to Step 4 |
4 | Replace the air bag wiring. Is the repair complete? | -- | -- | |
5 |
Is DTC 081 still shown as a current fault? | -- | Go to Step 6 | |
6 | Replace the driver side air bag sensor. Is the repair complete? | -- | -- |