When the ignition switch is turned to ON, the sensing and diagnostic module (SDM) will perform a turn-on test to diagnose critical malfunctions within the SDM itself.
The test ignition and deployment loop voltages are measured to ensure that they are within their normal voltage ranges. The SDM monitors the voltages at the driver low and the passenger low to detect shorts to ground or voltage in the deploy loops.
The SDM inspects the wiring connection to the passenger air bag module by letting the infinitesimal current flow through the internal circuit and verify the resistance.
• | The belt pretensioner wiring of passenger high is shorted to ground. |
• | The belt pretensioner wiring of passenger low is shorted to ground. |
Step | Action | Values | Yes | No |
---|---|---|---|---|
Caution: Refer to Sensing and Diagnostic Module Voltage after Ignition is Turned Off Caution in the Preface section. Caution: Refer to Sensing and Diagnostic Module Handling Caution in the Preface section. | ||||
1 | Perform the Diagnostic System Check - SIR. Is the Diagnostic System Check - SIR complete? | -- | Go to Step 2 | |
2 |
Is there any visible damage to the SIR harness? | ∞ | Go to Step 3 | Go to Step 4 |
3 |
Is the repair complete? | -- | -- | |
4 |
The shorting bar at the disconnected SDM connector will create a complete circuit between the wires from the passenger seat belt pretensioner module. Is the resistance less than the specified value? | ∞ | Go to Step 3 | Go to Step 5 |
5 |
Is DTC 015 still shown as a current fault? | -- | Go to Step 6 | System OK |
6 |
Is the repair complete? | -- | -- |