Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Remove the Instrument panel lower cover. Refer to
Instrument Panel Lower Trim Panel Replacement
in Instrument Panel,
Gages and Console.
- Remove the HVAC controller retaining screws.
- Remove the controller by pulling it out to provide clearance for the removal
of the cable.
Important: Note the location of the cables and the housings to facilitate their reinstallation.
- Disconnect the mechanical control cables by gently prying off the cable eyelet
and unsnapping the cable housing from the mechanical slide.
- Disconnect the electrical connectors.
Installation Procedure
- Connect the electrical connectors to the proper sockets on the back of the controller.
- Install the mechanical cable housings to the proper control positions.
- Install the eyelets on the end of each cable, pressing each onto the proper
post.
- Install the controller by gently inserting the controller into the proper
position on the center console.
Notice: Refer to Fastener Notice in the Preface section.
- Install the lower left and the lower right controller retaining screws.
Tighten
Tighten the HVAC controller retaining screws to 3 N·m (27 lb in).
- Install the instrument panel lower cover. Refer to
Instrument Panel Lower Trim Panel Replacement
in Instrument Panel,
Gages and Console.
- Connect the negative battery cable.
- Confirm the proper operation of the controller by moving it through all
of the controller's possible functioning positions.