Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Disconnect the breather hose from the valve cover.
- Remove the eight bolts from the valve cover.
- Remove the valve cover.
- Remove the valve cover gasket.
- Clean the sealing surfaces.
Installation Procedure
- Install the new valve cover gasket and the valve cover.
Notice: Refer to Fastener Notice in the Preface section.
- Install the eight bolts to the valve cover.
Tighten
Tighten the valve cover bolts to 9 N·m (80 lb in).
- Connect the breather tube to the valve cover.
- Connect the negative battery cable.