The number below refers to the step number on the diagnostic table.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Caution: Do not connect a jumper cable directly to the negative terminal of a discharged battery to prevent sparking and possible explosion of battery gases. | ||||
Does the bulb pass the visual and physical inspections? | -- | Go to Step 3 | Go to Step 2 | |
2 | Replace the bulb. Is the repair complete? | -- | System OK | -- |
3 |
Is fuse EF22 open? | -- | Go to Step 4 | Go to Step 5 |
4 |
Is the repair complete? | -- | System OK | -- |
5 | Test fuse EF22. Does the voltage at fuse EF22 equal the specified value? | 11-14 V | Go to Step 7 | Go to Step 6 |
6 | Repair the open power supply circuit for fuse EF22. Is the repair complete? | -- | System OK | -- |
7 |
Does the voltage at connector terminal 2 equal the value specified? | 11-14 V | Go to Step 8 | Go to Step 9 |
8 | Repair the open circuit between fuse EF22 and the interior courtesy lamp terminal 2. Is the repair complete? | -- | System OK | -- |
9 |
Does the ohmmeter indicate continuity? | -- | Go to Step 10 | Go to Step 11 |
10 | Replace the interior courtesy lamp switch assembly. Is the repair complete? | -- | System OK | -- |
11 | Repair the ground circuit for the interior courtesy lamp. Is the repair complete? | -- | System OK | -- |