Locate the lever lock on the wire dress cover. While pressing the lock,
pull the lever over and past the lock.
Disconnect the connector from the component.
Locate
the 2-wire dress cover locking tabs that are opposite the wire end of the connector.
Use a small flat-bladed tool to unlock the dress cover.
Once the front 2 locks are unlocked, lift the back 2 locks that are on
the wire side of the connector.
If
the connector has a nose piece, use a small flat-bladed tool to remove the nose piece
by inserting the blade into the slot on the front of the connector and prying up
on the nose piece.
Important: Always use care when removing a TPA in order to avoid damaging it.
Remove the TPA by inserting a small flat-blade tool into the small slot on
the TPA and pushing down until the TPA comes out of the connector. Gently pry the
TPA out of the connector.
Insert J 44020
-4 (GM P/N 15314260) into the
2 triangular cavities on each side of the terminal at the front of the connector.
While
holding the removal tool in place, gently pull the wire out of the back of the connector.
Always remember never use force when pulling a terminal out of a connector.