Diagnostic Instructions
DTC Descriptors
DTC P0506: Idle Speed Low
DTC P0507: Idle Speed High
Circuit/System Description
The engine control module (ECM) controls the engine idle speed by adjusting the position of the idle air control (IAC) valve pintle. The IAC valve is a stepper motor driven by 2 internal coils. The movement of the IAC valve is controlled electrically
by four circuits. Drivers within the ECM control the polarity of the 2 windings inside the IAC valve through these circuits. The ECM, by commanding the correct polarity in sequence, is able to command the motor within the IAC valve to rotate clockwise
or counterclockwise in steps. In order for the armature of the stepper motor of the IAC valve to turn one revolution, it needs to move approximately 24 steps. The IAC valve motor is linked by a gear drive to the IAC valve pintle. The electrical pulses
sent to the IAC valve coils, by the ECM, allows the pintle to extend or retract into the passage in the throttle body. By retracting the pintle, air is allowed to bypass the throttle valve, which will increase air flow and raise engine speed. When the pintle
is extended, bypass air is decreased which lowers engine speed. IAC valve movement is measured in counts on the scan tool. Each count is equivalent to a step of the IAC valve. When the IAC valve is fully extended, and seated in the throttle body bore, the scan
tool displays zero and the engine speed is slow. As the IAC valve pintle retracts the counts will raise along with engine speed.
The IAC valve the following circuits:
IAC Valve Reset
When the ignition switch is turned OFF for more than 10 seconds an IAC valve reset occurs. At that time, the ECM commands the IAC valve to extend for a certain period which allows the IAC pintle to seat in the throttle body bore. This position is
then sensed as zero count position for the IAC valve by the ECM. It must be observed that the IAC valve position is only sensed by the ECM measuring counts or steps of the driver circuit, there is no direct sensing of its exact position. When this extend time
period ends, the ECM then commands the IAC valve to retract a predetermined amount. This will allow for a high engine speed on the next ignition cycle. If for any reason the IAC valve pintle moves after this reset, before the next ignition cycle, the ECM will
not be able to detect it and will affect the ability to control engine idle. When the IAC valve is removed for any reason the reset must be performed.
Conditions for Running the DTC
• | DTCs P0106, P0107, P0108, P0112, P0113, P0117, P0118, P0121, P0123, P0131, P0132, P0133, P0134, P0135, P0141, P0171, P0172, P0201, P0202, P0203, P0204, P0300, P0301, P0302, P0303, P0304, P0336, P0337, P0341, P0342, P0351, P0352, P0402, P0404,
P0405, P0406, P0443, P0502, P01167, P1171, and P1404 are not set. |
• | The engine run time is greater than 60 seconds. |
• | The manifold absolute pressure (MAP) is less than 60 kPa . |
• | The barometric pressure (BARO) is greater than 72 kPa. |
• | The intake air temperature (IAT) is greater than -20°C (-4°F). |
• | The engine coolant temperature ( ECT) is greater than 60°C (140°F). |
• | The ignition voltage is between 11-16 volts. |
• | The DTCs run when the above conditions are met for 5 seconds. |
Conditions for Setting the DTC
DTC P0506
The actual engine speed is less than the desired idle speed by at least 100 RPM for 10 seconds.
DTC P0507
The actual engine speed is more than the desired idle speed by at least 200 RPM for 10 seconds.
Action Taken When the DTC Sets
DTCs P0506, and P0507 are Type B DTCs.
Conditions for Clearing the DTC
DTCs P0506, and P0507 are Type B DTCs.
Reference Information
Schematic Reference
Engine Controls Schematics
Electrical Information Reference
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool Reference
Control Module References for scan tool information
Special Tools Required
J 37027-A Idle Air Control Motor Analyzer
Circuit/System Verification
- Engine running for 1 minute, observe the DTC Information with a scan tool. DTCs P0506 and P0507 should not set.
- Operate the vehicle within the Conditions for Running the DTC to verify the DTC does not reset. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the IAC valve.
- Connect the
J 37027-A to the IAC valve.
- Engine running, command the IAC valve in until 600 RPM is reached with the
J 37027-A , then command the IAC valve out until 1,800 RPM is reached, then lower the idle to 800 RPM. The engine
speed should steadily increase and decrease as commanded.
⇒ | If the idle does not increase or decrease steadily, verify one of the following conditions is not present: |
• | Excessive deposits on the throttle plate or bore |
• | Excessive deposits on IAC valve pintle or bore |
• | Restricted air intake system |
• | The throttle body for damage and/or tampering |
• | Malfunctioning PCV valve |
⇒ | If all conditions test normal, test or replace the IAC valve. |
Important: This test must be performed on all of the IAC control circuits.
- Engine running, command the IAC valve out until 1,800 RPM is reached then lower the idle to 800 RPM with the
J 37027-A . The test lamp should flash.
• | IAC A High Control terminal D |
• | IAC A Low Control terminal C |
• | IAC B High Control terminal B |
• | IAC B Low Control terminal A |
⇒ | If the test lamp does not illuminate, test the applicable control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp does illuminate, and does not flash, test the applicable control circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If test lamp illuminates and flashes, test the applicable control circuit for high resistance. If the circuit tests normal, replace the ECM. |
- If all circuits test normal, test or replace the IAC valve.
Component Testing
- Ignition OFF, disconnect the harness connector at the IAC valve.
- Test for 40-80 ohms of resistance between the following terminals of the IAC valve:
⇒ | If not within the specified range, replace the IAC valve. |
- Test for infinite resistance between the following terminals of the IAC valve:
⇒ | If less than the specified value, replace the IAC valve. |
- Test for infinite resistance between each terminal and the IAC valve housing .
⇒ | If less than the specified value, replace the IAC valve. |
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic procedure.