Tools Required
J-36649
Cooling System Pressure Test Adapter
The surge tank cap maintains proper pressure, protects the system from high pressure by opening a pressure valve, and protects the coolant hoses from collapsing because of a vacuum.
- Wash any sludge from the surge tank cap and the valve seat of the vacuum pressure valve for the surge tank cap.
- Check for any damage or deformity to the vacuum pressure valve for the surge tank cap. If any damage or deformity is found, replace the cap.
- Install a suitable cooling system pressure tester to the cap using the
J-36649
.
- Pull the vacuum pressure valve open. If the surge tank cap does not seal properly, replace the surge tank cap.
- Pressurize the cap to 120-160 kPa (17-23 psi).
- Wait 10 seconds and check the pressure held by the tank cap tester.
- If the pressure held by the cooling system pressure tester falls below 80 kPa (16 psi), replace the surge tank cap.