Removal Procedure
- Remove the EVAP canister vent.
- Disconnect the inlet and outlet hose from the EVAP canister.
- Remove the EVAP canister bracket retaining bolt.
- Remove the EVAP canister (1).
Installation Procedure
- Install the EVAP canister (1).
Caution: Refer to Fastener Caution in the Preface section.
- Install the EVAP canister bracket retaining bolt.
Tighten
Tighten evaporative emission canister bracket retaining bolt to 8 N·m (71 lb in).
- Connect the inlet and outlet hose to the EVAP canister.
- Install the EVAP canister vent.